Описание

  • Front panel installation at rear or with front plate
  • Switch with actuating directions 1-4
  • One changeover contact with screw terminal for each actuating direction
  • Bellows
Dimension drawing Dimension drawing Wiring diagram Wiring diagram Wiring diagram Switching functions Dimension drawingDimension drawingWiring diagramWiring diagramWiring diagramSwitching functions Technical dataApprovals Mechanical values and environment
Material
Bellows elastomer black
Housing thermoplastic/aluminum
Switching lever galvanized steel
Weight
Net 0,65 kg
Ambient temperature -25 ... 65 °C Latching version
Degree of protection IP65 on the front with bellows
Mechanical life min.1 x 106
Contact material Silver alloy
Switching principle Changeover contact ZA IEC 947-5-1
Mounting method 1x hole 42 and 8x 4.5 for M4
Number of monitoring contacts 4
Connection Screw terminal
Actuating directions 4
Electrical connection ratings
Utilization category according to EN 60947-5-1
AC-15 230V 10A
DC-13 24V 4A
Short circuit protection according to IEC 60269-1 T16 / F25
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage min.24 V
Switching current
(at 24V) min.50 mA
Other
Additional feature Bellows
''