Описание

  • Front panel installation according to IEC 947-5-1 D30
  • Push button with actuating directions 1-4
  • One changeover contact with tab connector 2.8 x 0.5 IEC 760 for each actuating direction
  • Locking in central position
  • Pushbutton in handle
Dimension drawing Dimension drawing Wiring diagram Wiring diagram Wiring diagram Wiring diagram Switching functions Dimension drawingDimension drawingWiring diagramWiring diagramWiring diagramWiring diagramSwitching functions Technical dataApprovals Mechanical values and environment
Material
Housing thermoplastic/aluminum
Switching lever stainless steel
Bellows elastomer black
Weight
Net 0,17 kg
Ambient temperature -5 ... 65 °C Spring return version
Degree of protection IP54 on the front without bellows
Mechanical life min.1 x 106
Contact material Silver alloy
Switching principle changeover contact C IEC 947-5-1
Mounting method IEC 947-5-1 D30
Number of monitoring contacts 4
Connection Tab connector 2.8x0.5 IEC760
Actuating directions 4
Pushbutton in handle
Electrical life 0,5 x 106
Switching principle 1 contact
Actuating force 3 N
Mechanical life 0,5 x 106
Electrical connection ratings
Utilization category according to EN 60947-5-1
AC-15 230V 4A
DC-13 24V 2A
Short circuit protection according to IEC 60269-1 Slow-blow T6 / quick-blow F10
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage min.10 V
Switching current
(at 24V) min.12 mA
Pushbutton in handle
Test voltage
AC 1 kV
Switching voltage
DC 10 ... 50 V
Other
Additional feature
Pushbutton in handle
Comment: Interlocking
''