Описание

  • Auxiliary release on the front
  • Without door monitoring contact
  • Increased horizontal overtravel
Approach direction Horizontal and vertical Can be adjusted in 90° steps Increased overtravel for horizontal approach direction Solenoid operating voltage
  • AC 110 V +10%, -15%
    Guard locking type
    TP1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.
    Switching element
    4131Slow-action switching contact 2 NC + 2 NO
    Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
    Housing material Reinforced thermoplastic
    Weight
    Net 0,5 kg
    Ambient temperature -20 ... 55 °C
    Degree of protection IP67
    Mechanical life 1 x 106
    Contact material Silver alloy, gold flashed
    Switching principle Slow-action switching contact
    Installation orientation Any
    Number of door position positively driven contacts 2
    Number of NO contacts 2
    Connection
    3 x M20 x 1.5
    Approach speed
    max. 20 m/min
    Actuation frequency 1200 1/h
    Guard locking principle Closed-circuit current principle
    Locking force Fmax 1300 N
    Locking force FZh 1000 N
    Retention force 10 N
    Extraction force 20 N
    Actuating force 10 N
    Electrical connection ratings
    Thermal rated current Ith 4 A
    Utilization category according to EN 60947-5-1
    AC-15 4A 230V
    DC-13 4A 24V
    Solenoid operating voltage
    AC 110 V -15% ... +10%
    Short circuit protection according to IEC 60269-1
    (Fuse) 4A gG
    Rated insulation voltage Ui 250 V
    Rated impulse withstand voltage Uimp 2,5 kV
    Switching voltage
    Min. at 10mA 12 V
    Switching current
    Min. at 24V 1 mA
    Power consumption 10 W
    Solenoid duty cycle 100 %
    Connection cross-section 0,34 ... 1,5 mm?
    Reliability values according to EN ISO 13849-1
    Monitoring of guard locking and the safety guard position
    B10D 3 x 106
    Control of the guard locking
    Category Depending on external control of guard locking
    Performance Level Depending on external control of guard locking
    PFHD Depending on external control of guard locking
    In combination with Actuator BETAETIGER-P-GTMechanical values and environment
    Overtravel A B C D E 2 mm
    Overtravel K L M N 1,5 mm
    In combination with Actuator BETAETIGER-P-GNTMechanical values and environment
    Overtravel A B C D E 7 mm
    ''