Описание

  • Compact housing
  • Mechanical release from 3 sides
  • Any installation position
  • LED indicator
  • connection cable 5m
Guard locking types
TQ1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.
Switching elements
SKFor monitoring the door/actuator position.
UKMonitoring contact for monitoring the guard locking (built-in solenoid).
1202SSlow-action switching contact 2 NC + 2 NC + 1 NO
Auxiliary release This releases the guard locking after operation with a triangular key (included).
Housing material Reinforced thermoplastic
Weight
Net 0,5 kg
Ambient temperature -20 ... 50 °C
Degree of protection IP67
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position positively driven contacts 2
Number of door position NO contacts 1
Number of guard lock monitoring NC contacts 2
Connection Connection cable 5m
Approach speed 0,05 ... 1 m/min
Actuation frequency 900 1/h
Guard locking principle Closed-circuit current principle
Locking force Fmax 500 N
Retention force 1 N
Extraction force 10 N
Actuating force 5 N
Insertion depth 26,3 mm
Electrical connection ratings
Thermal rated current Ith 2,5 A
Utilization category according to EN 60947-5-1
AC-15 0.75A 250V
1A 125V
DC-13 0.27A 250V
0.22A 125V
Solenoid operating voltage
DC 24 V -15% ... +10%
Short circuit protection according to IEC 60269-1
(Fuse) 2A gG
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Power consumption 2,7 W
Solenoid duty cycle 100 %
Reliability values according to EN ISO 13849-1
Monitoring of the position of the safety guard
B10D 2 x 106
Control of the guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHD Depending on external control of guard locking
In combination with Actuator BETAETIGER-Q-GT, RADIUSBETAETIGER-Q-RO, RADIUSBETAETIGER-Q-LU, BETAETIGER-Q-WTMechanical values and environment
Overtravel A B C D E 1,9 mm
In combination with Actuator BETAETIGER-Q-WTBMechanical values and environment
Overtravel A B C D E 1,3 mm
''