Описание

  • Auxiliary release on the front
  • Two LED indicators, red and green
  • Actuating head fitted left
Approach direction Horizontal Can be adjusted in 90° steps Solenoid operating voltage and LED function display
  • 24 V AC/DC -15%, +10%
Guard locking type
TZ1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.
Switching element
SKFor monitoring the door/actuator position
UKFor monitoring the guard locking (built-in solenoid)
528HSlow-action switching contact 1 NC + 1 NO
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. Sealing can be fitted to protect against tampering. Lead seal kit and tool included (already pre-assembled on versions with plug connectors).
Housing material
Weight
Ambient temperature -25 ... 80 °C
Degree of protection
Mechanical life 1 x 106
Contact material
Switching principle
Installation orientation
Number of door position positively driven contacts 1
Number of door position NO contacts 1
Number of guard lock monitoring positively driven contacts 1
Number of guard lock monitoring NO contacts 1
Connection
Approach direction
Approach speed max.20 m/min
Actuation frequency 1200 1/h
Guard locking principle
Locking force Fmax 2000 N
Locking force FZh 1500 N
Retention force 10 N
Extraction force 30 N
Actuating force 35 N
Insertion depth min.52 mm
Cover lid
Electrical connection ratings
Thermal rated current Ith 4 A
Utilization category according to EN 60947-5-1
AC-15
DC-13
Solenoid operating voltage
Short circuit protection according to IEC 60269-1
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Switching current
Power consumption 10 W
Solenoid duty cycle 100 %
Connection cross-section 0,34 ... 1,5 mm?
LED indicator
In combination with Actuator BETAETIGER-Z-GMechanical values and environment
Overtravel 4 mm
In combination with Actuator BETAETIGER-Z-GNMechanical values and environment
Horizontal overtravel (A B C D E) 16 mm
''