Описание

  • Without auxiliary release
  • Two LED indicators, red and green
  • Plug connector for switch connection
  • Plug connector for enabling switch
  • Actuating head fitted left
Approach direction Horizontal Can be adjusted in 90° steps Solenoid operating voltage and LED function display
  • 24 V AC/DC -15%, +10%
Guard locking type
TZ1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.
Switching elements
SKFor monitoring the door/actuator position
UKFor monitoring the guard locking (built-in solenoid)
2131HSlow-action switching contact 3 NC + 1 NO
3131HSlow-action switching contact 2 NC + 2 NO
Housing material Anodized die-cast alloy
Weight
Net 1,2 kg
Ambient temperature -25 ... 80 °C
Degree of protection IP65
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position positively driven contacts 2
Number of door position NO contacts 1
Number of guard lock monitoring positively driven contacts 2
Number of guard lock monitoring NO contacts 1
Connection
1 x Plug connector RC18
Approach speed max.20 m/min
Actuation frequency 1200 1/h
Guard locking principle Closed-circuit current principle
Locking force Fmax 2000 N
Locking force FZh 1500 N
Retention force 10 N
Extraction force 30 N
Actuating force 35 N
Insertion depth min.52 mm
Cover lid Black
Electrical connection ratings
Thermal rated current Ith 4 A 70°C => 2A'>
Utilization category according to EN 60947-5-1
AC-15 4A 110V 70°C => 2A'>
DC-13 4A 24V 70°C => 2A'>
Solenoid operating voltage
AC/DC 24 V -15% ... +10%
Short circuit protection according to IEC 60269-1
(Fuse) 4A gG 70°C => 2A gG'>
Rated insulation voltage Ui 110 V
Rated impulse withstand voltage Uimp 1,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Power consumption 10 W
Solenoid duty cycle 100 %
LED indicator Operating voltage corresponds to the solenoid voltage
Other
C number
C1803 Without mechanical release with connection for enabling switch (RC12)
Reliability values according to EN ISO 13849-1
Control of the guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHD Depending on external control of guard locking
Monitoring of guard locking and the safety guard position
B10D 3 x 106
In combination with Actuator BETAETIGER-Z-GMechanical values and environment
Overtravel 4 mm
In combination with Actuator BETAETIGER-Z-GNMechanical values and environment
Overtravel 16 mm
''