Описание

  • Interface adapter with 4-bit parallel interface
  • Usage in conjunction with Electronic-Key adapter FHM
  • A complete read-only system consists of an Electronic-Key adapter FHM and a modular interface adapter
  • Simple connection
  • Read-only system
  • Internal evaluation of the data from the Electronic-Key
  • Output of the access level via 4-bit parallel interface
  • Has all operating states
  • Connection to PLC
  • Version FSA (For Safety Applications)
Dimension drawing Wiring diagram Dimension drawingWiring diagram Technical dataApprovals Mechanical values and environment
Housing material PA6.6 gray
Ambient temperature 0 ... 55 °C
Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
Number of read heads max.1
Connection Plug-in screw terminal
Electrical connection ratings
LED indicator
Green Operational
Yellow Key in the operating distance
Red Fault
Connection cross-section 0,14 ... 2,5 mm?
Parameters for floating semiconductor switching contact LA
Switching voltage 24 ... 30 V
Switching current 1 ... 10 ... 50 mA In event of short circuit the output is shut down
Utilization category according to EN 60947-5-1
AC-15 24V 50mA
AC-12 24V 50mA
DC-12 24V 50mA
Utilization category according to EN 60947-5-2
DC-13 24V 50mA
Interface and signaling
Switching voltage UB-2 ... UB V High signal
Switching current 1 ... 10 ... 50 mA High signal
Power supply
Operating voltage DC 9 ... 24 ... 28 V DC
Current consumption max.70 mA
Interface, bus
Interface and signaling
Data interface 4-bit parallel plus strobe, binary coded via High/Low level
Other
Parameters for floating semiconductor switching contact LA
Additional feature
35 Resistance in switched-on state in Ohm
max.1 Capacitive load on output in µF
''