Описание

  • Key adapter with integrated CES read head
  • Suitable for connection to a CES-AZ evaluation unit or CES-FD field unit
  • Simple connection via plug connector M8
  • Front cover: red
  • High degree of protection IP 67
  • LED indicator
Important:Keys must be ordered separately!
Housing material PA6-GF30
Weight
Net 0,13 kg
Ambient temperature -20 ... 70 °C
Degree of protection
On installation in flat metal plate, thickness = 2mm IP67 in installed state (only access side)
Mounting method Fastening using screw clamp elements on rear
Mounting cut-out according to DIN 43700 33 x 68 mm
Installation orientation On the front
Tightening torque
Fixing screws in the clamping pieces on the rear 0,25 ... 0,35 Nm
Switching frequency See operating instructions for the related evaluation unit
Connection M8 plug connector, 3-pin
Cable length
Maximum allowed max.25 m
Method of operation Inductive
Electrical connection ratings
Power supply Via evaluation unit
LED indicator White: valid actuator detected
Work area
Switching hysteresis 1 mm
Assured switch-off distance Sar max.30 mm
Assured operating distance Sao min.2 mm
''