Описание

  • Locking (without guard locking)
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • With plug connector RC18
  • With escape release
  • Unicode
Door stop A mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier. LED indicator The LED indicator indicates all important system and status information. Monitoring outputs
OTBolt tongue inserted into the evaluation module
OIDiagnostics, there is a fault
Escape releaseThe escape release enables people accidentally shut in to open the guard locked door from the danger zone. Dimension drawing Dimension drawing Plug connector RC18 MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Changing single wiring (AP) to series wiring (AR) MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawingDimension drawingPlug connector RC18 Technical data Interlocking module MGB-L0-ARA-AA1A1-S1-R-111937 (Order no. 111937) Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 0,75 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP65
Mechanical life 1 x 106
In case of use as door stop, and 1 Joule impact energy 0,1 x 106
Installation orientation Door hinge DIN right
Switching frequency 0,25 Hz
Connection Plug connector RC18
Electrical connection ratings
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1,5 kV
Degree of contamination (external, according to EN 60947-1) 3
Safety class III
Discrepancy time
Between FO1A and FO1B max.10 ms
Risk time according to EN 60947-5-3 max.350 ms
Transponder coding Unicode
Power supply UB
Operating voltage DC
UB 24 V DC -15% ... 10%
Current consumption
IUB max.80 mA
Power supply UA
Operating voltage DC
UA 24 V DC -15% ... 10%
Current consumption
IUA max.10 mA
Safety outputs FO1A, FO1B
Test pulses max.1 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage
UFO1A /UFO1B HIGH UB-2V ... UB V DC
UFO1A /UFO1B LOW 0 ... 1 V DC
Output current
Per safety output FO1A / FO1B 1 ... 200 mA
Monitoring outputs OD, OT, OL, OI
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC
Output current max.50 mA
Other
Product version number V3.0.0
Reliability values according to EN ISO 13849-1
Monitoring of the position of the safety guard
Category 4
Performance Level PL e
PFHD 3.7 x 10-9
Mission time 20 y
Handle module MGB-H-AA1A3-R-111157 (Order no. 111157) Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 1,00 kg
Ambient temperature -20 ... 55 °C
Degree of protection IP65
Installation orientation Door hinge DIN right
Other
Additional feature With automatic lockout mechanism
Product version number V3.0.0
Escape release MGB-E-A-100465 (Order no. 100465) Mechanical values and environment
Housing material Die-cast zinc/stainless steel powder-coated
Weight
Net 0,75 kg
Ambient temperature -20 ... 55 °C
Mechanical life 1 x 106
Installation orientation Any
Other
Product version number V2.0.0
Components 111937 Interlocking module MGB-L0-ARA-AA1A1-S1-R-111937
  • Locking (without guard locking)
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • With plug connector RC18
  • Unicode
111157 Handle module MGB-H-AA1A3-R-111157
  • Intelligent bolt tongue
  • Fold-out lockout mechanism
  • Second automatically extending lockout mechanism
  • Door handle
100465 Escape release MGB-E-A-100465
  • Escape release from the danger zone
  • Door handle signal red
  • Extended actuation axis for thicker doors (available optionally)
''