Описание

  • Guard locking with guard lock monitoring
  • Emergency stop according to ISO 13850
  • 8 pushbuttons illuminated
  • Operating mode selector switch
  • 1 indicator
  • Including adhesive labels
  • Push-pull plug
  • Including terminal plug for enabling switch (RC12, 12-pin)
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
  • With escape release
  • Multicode
Profinet connection Connection via push-pull plugs according to IEC 61076-3-117 Profinet RT switch Point-to-point topology network structure due to integrated RT switch. Flexible use as interlocking or guard locking By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring). Escape releaseThe escape release enables people accidentally shut in to open the guard locked door from the danger zone. Dimension drawing MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawing Technical data Escape release MGB-E-A2-106051 (Order no. 106051) Mechanical values and environment
Housing material Die-cast zinc/stainless steel powder-coated
Weight
Net 1,05 kg
Ambient temperature -20 ... 55 °C
Mechanical life 1 x 106
Installation orientation Any
Other
Additional feature With mounting plate
Product version number V2.0.0
Handle module MGB-H-AA1A6-R-111838 (Order no. 111838) Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 1,00 kg
Ambient temperature -20 ... 55 °C
Degree of protection IP65
Installation orientation Door hinge DIN right
Other
Additional feature With mounting plate and automatic lockout mechanism
Product version number V3.0.0
Locking module MGB-L2CB-PN-R-106053 (Order no. 106053) Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 4,05 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP54
Resilience to vibration In accordance with EN 60947-5-3
Mechanical life 1 x 106
In case of use as door stop, and 1 Joule impact energy 0,1 x 106
Installation orientation Door hinge DIN right
Reaction time
Enabling switch max.250 ms Switch-off time
Operating mode selector switch max.220 ms Switch-off time
Emergency stop / machine stop max.250 ms Switch-off time
Door position max.550 ms Switch-off time
Bolt position max.550 ms Switch-off time
Guard locking max.550 ms Switch-off time
Switching frequency 0,25 Hz
Connection
Push-pull power
Push-pull power
According to IEC 61076-3-117 variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45
Push-pull RJ45
Plug connector RC12
Guard locking principle Open-circuit current principle
Locking force FZh 2000 N
Electrical connection ratings
Current consumption max.500 mA
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0,5 kV
Maximum feed-in current in the connection block
X1, X2 max.4000 mA
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
Degree of contamination (external, according to EN 60947-1) 3
Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Safety class III
Transponder coding Multicode
Power supply X1
Operating voltage DC
L1 24 V DC -15% ... 10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Fusing
external min.1 A Slow blow
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... 10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Work area
Assured switch-off distance Sar max.65 mm
Interface, bus
Data interface
Data protocol
Bus protocol Profinet (IEC 61158 type 10)
Safety protocol Profisafe (IEC 61784-3-3)
Other
Product version number V3.30.10
Slide-in label
S-Zone Secured
Line Stop
Cooling Water Extraction On
Cooling Water Extraction Off
Safety Gate Open
S-Zone Reset
Anlage Start
Anlage Stopp
Cooling water on
Cooling water off
Open safety door
S-Bereich Quittieren
S-Bereich Gesichert
Line Start
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
Category 4
Performance Level PL e
PFHD 4.07 x 10-8
Diagnostic Coverage (DC) 99
Emergency stop
B10D
Emergency stop 0.1 x 106
Emergency-stop evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Selector switch evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Enabling switch
B10D
Enabling switch According to manufacturer’s specifications
Enabling switch evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Safety Integrity Level SIL 3 (EN 62061:2005)
Mission time 20
Components 106051 Escape release MGB-E-A2-106051
  • Escape release out of the danger area
  • Mounted on mounting plate
  • With red handle
  • 118 mm long
111838 Handle module MGB-H-AA1A6-R-111838
  • Intelligent bolt tongue
  • Fold-out lockout mechanism
  • Second automatically extending lockout mechanism
  • Door handle
  • Mounting plate
106053 Locking module MGB-L2CB-PN-R-106053
  • Guard locking with guard lock monitoring
  • Emergency stop according to ISO 13850
  • 8 pushbuttons illuminated
  • Operating mode selector switch
  • 1 indicator
  • Including adhesive labels
  • Push-pull plug
  • Including terminal plug for enabling switch (RC12, 12-pin)
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
  • Multicode
''