Описание

  • Freely programmable small safe control system
  • 8 single-channel /4 dual-channel inputs
  • 2 control inputs
  • 2 semiconductor outputs (PL e, category 4)
  • 2 door monitoring outputs
  • PC connection for the software EUCHNER Safety Designer
  • Optional memory module for configuration
  • Compact housing with width of only 22.5mm
  • Straightforward diagnostics via LED displays
  • Plug-in screw terminals
Safety relay. Freely programmable safe small control system with eight single-channel or four dual-channel inputs. The base module also features two control inputs, two safe outputs and two monitoring outputs.
Dimensions 108 x 22.5 x 114.5
Material
Housing Polyamide
Ambient temperature -10 ... +55 °C
Atmospheric humidity 10 ... 95 % rH
Degree of protection IP20
Mounting method Mounting rail 35mm
Connection Plug-in screw terminal
Cable length max.100 m 1mm?'>
USB port for PC connection
Connection USB type B - Mini
Cable length max.3 m USB cable
Safety outputs OSSD1, OSSD2
Number of safety outputs 2
For module activation
Number of inputs 2
Safety input 1...8
Number of inputs 8
External relay monitoring (EDM), automatic, manual operation
Number of inputs 2
Status (can be programmed via software)
Number of monitoring outputs 2
Pulse output 1...4
Number of outputs 4
Electrical connection ratings
Operating voltage DC
UB 24 V DC -20% ... +20% PELV
Overvoltage category according to IEC EN 60664-1 II
Degree of contamination according to EN 60664-1 2
Connection cross-section 0,2 mm? 0,5 ... 2,5 mm? Screw terminal
Delay time 0,0106 ... 0,0546 s + filter time
Power consumption max.3 W
Safety outputs OSSD1, OSSD2
Test pulses 0,1 ms
Inductive load max.30 mH
Capacitive load max.0,82 ?F
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage
HIGH UB-0,75 ... UB V DC
LOW 0 ... 2 V DC
Output current
Max. load at 24VDC - ... 400 mA
For module activation
Type of input Semiconductor inputs, p-switching
Safety input 1...8
Type of input Semiconductor inputs, p-switching
External relay monitoring (EDM), automatic, manual operation
Type of input Semiconductor inputs, p-switching
Status (can be programmed via software)
Type of output Semiconductor outputs, p-switching
Output current max.100 mA
Pulse output 1...4
Test pulses 0,2 ms
Type of output Semiconductor outputs, p-switching
Reliability values according to EN ISO 13849-1
ESPE type 4
Performance Level PL e
Category 4
PFHD 6.06E-9 1/h
SIL CL 3
Mission time 20 y
''