Описание

  • 100 detent positions per revolution
  • Wear-free magnetic detent mechanism
  • 100 pulses per revolution
  • Installation in operator panels and EUCHNER hand-held pendant stations HBL
Notes
  • Output G05 suitable for Fanuc control systems
Dimension drawing Wiring diagram Ausgangssignale Hand-held pendant stations and hand wheels Dimension drawingWiring diagramAusgangssignale Technical dataApprovals Mechanical values and environment
Material Aluminum
Weight
Net 0.5
Ambient temperature 0 ... 70 °C
Atmospheric humidity
(condensation not permissible) 0.8
Degree of protection
IEC 529 IP65
acc. to NEMA 250 250-12
Resilience to vibration
Vibration (3 axes) DIN/IEC 68-2-6
Shock (3 axes) DIN/IEC 68-2-27
Connection Ribbon cable with socket connector DIN 41651 6-pin
Detent positions per revolution 100
Electrical connection ratings
Operating voltage DC 5 V DC -5% ... 5%
Current consumption
Without load max.80 mA
EMC protection requirements
Acc. to CE EN 61000-6-2, EN 61000-6-4
Type of output Push-pull
Pulses per revolution 2x100
Output voltage
High(1) min.4,0 V DC at 0 mA
min.3,4 V DC at 5 mA
min.3,0 V DC at 20 mA
Low(0) max.1,3 V DC at 15 mA
Other
Detent mechanism Magnetic
''