Описание

  • Serial interface RS232/RS422
  • In combination with read head CIT3ASX1N12ST
  • DIN rail mounting
Serial interfaceThe individual commands for reading and writing the data carrier are in accordance with the common 3964R protocol and are described in the EUCHNER CIS3 system manual (order no. 084 727). For data carrier programming away from the system, a convenient WINDOWS®-compatible PC software application is available (Software Transponder Coding) Attention:
  • On the usage of a screened cable the connection cable for the serial interface is allowed to be max. 5 m long for RS232 and max. 1000 m long for RS422.
  • On the usage of a screened cable the connection cable to the write/read head is allowed to be max. 15 m long.
  • It is only ever possible to connect 1 read head per interface adapter.
Housing material PA 6.6
Ambient temperature 0 ... 55 °C
Degree of protection IP20
Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
Number of read heads max.1
Connection Plug-in screw terminals
Cable length
max.5 m RS232
max.1000 m RS422
Electrical connection ratings
Operating voltage DC 20 ... 24 ... 28 V DC
Current consumption 65 mA max.100 mA
LED indicator
Green STATE LED operational
Yellow ACTIVE LED data carrier active
Connection cross-section 0,14 ... 2,5 mm?
Interface, bus
Data protocol 3964R via RS232/RS422
Data rate Can be selected via DIP switches
Other
Additional feature
Moisture test (not condensing) at +50°C and 80% rel. h
Vibration - IEC60068-2-6 amplitude 1mm, 10-55Hz, 3 axes
Shock - IEC60068-2-27 acceleration 30g, 6 shocks per axis, 11ms/half sinewave
In combination with Read head CIT3ASX1N12ST and Data carrier CIS3AP10D05KH01K, CIS3AP10D05KH01K-POperating distance
Read distance
With center offset m=0 0 ... 3 ... 6,5 mm
0 ... 3 ... 6 mm
0 ... 3 ... 5 mm
Center offset
Read distance s = 3 mm max.2,5 mm
Write distance s = 3 mm max.2 mm
Write distance
With center offset m=0 0 ... 3 ... 6 mm
0 ... 3 ... 4,5 mm
0 ... 3 ... 5,5 mm
''