Описание

  • Safety switch with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • With 1 plug connector M12, 8-pin
  • Unicode
  • Door monitoring output
  • Indication of the door position by LED
  • Escape release, 75 mm long
  • Approach direction A (default setting on delivery)
Approach direction Horizontal Can be adjusted in 90° steps Safety switchThe device may be operated only in conjunction with the actuator CET-A-.... Important: The actuator must be ordered separately. Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Solenoid operating voltage
  • DC 24 V +10% -15%
Guard locking type
CET3Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active.
LED function display
LED StateStatus LED
LED DIADiagnostic LED
LED 1 rdilluminates when the solenoid is energized
LED 2 gnilluminates when door is closed
Additional connections
OUTMonitoring output (semiconductor)
OUT DDoor monitoring output
Category according to EN ISO 13849-1Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN ISO 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated. The category is dependent on the installation position of the safety switch: Dimension drawing Wiring diagram Block diagram CET: Transponder-coded safety switch with guard locking CET3-AP: Mounting and Setup CET3-AP (closed-circuit current principle) CET3-AP: Mounting auxiliary release with key CET3-AP CET3-AP: Mounting emergency release safety swith CET3-AP Dimension drawingWiring diagramBlock diagram Technical dataApprovals Mechanical values and environment
Housing material
Slide Stainless steel
Safety switch housing Die-cast aluminum
Weight
Net 1 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Mechanical life 1 x 106
Installation orientation Any
Degree of freedom
Z ±4 mm
Y ±5 mm
X ±5 mm
Ready delay 1 s
Switching frequency max.0,5 Hz
Connection 1 plug connector M12, 8-pin
Approach speed 20 m/min
Guard locking principle Closed-circuit current principle
Locking force Fmax 6500 N
Locking force FZh 5000 N
Electrical connection ratings
Operating voltage DC
LED 24 V DC -15% ... 10%
UB 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Current consumption
ICM 480 mA
IB 80 mA
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Solenoid operating voltage DC
UCM 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Fusing
External (operating voltage UB) 0,25 ... 8 A
External (solenoid operating voltage UCM) 0,5 ... 8 A
Power consumption
Solenoid max.12 W
EMC protection requirements In acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1) 3
Connecting cable 30V DC, 2A
Safety class
EN IEC 61140 III
Switching load
According to UL 24V DC, class 2
Safety outputs OA/OB
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output OA / OB 1 ... 200 mA
Output voltage
High U(OA) / U(OB) UB-1,5V ... UB V DC
Low U(OA) / U(OB) 0 ... 1 V DC
Off-state current Ir max.0,25 mA
Risk time according to EN 60947-5-3
Single device max.400 ms
Switch-on time 400 ms
Discrepancy time
Both safety outputs max.10 ms
Monitoring output OUT
Type of output p-switching, short circuit-proof
Switching current
OUT 1 ... 50 mA
Output voltage
OUT 0,8xUB ... UB V DC
Switching delay from state change max.400 ms
Monitoring output OUT D
Type of output p-switching, short circuit-proof
Switching current
OUT D 1 ... 50 mA
Output voltage
OUT D 0,8xUB ... UB V DC
Switching delay from state change max.700 ms
Work area
Repeat accuracy R 10 %
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
Reliability values according to EN ISO 13849-1
Performance Level PL e
Category
Head upward 3
Head downward or horizontal 4
PFHD
Head downward or horizontal 3.1 x 10-9
Head upward 4.29 x 10-8
Mission time 20 y
''