Описание

  • Safety switch with guard locking and integrated evaluation electronics
  • Version with stainless-steel components
  • ECOLAB certificate
  • Short circuit monitoring
  • Two safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • With plug connector M12
  • Unicode
  • Door monitoring output
  • With escape release
  • Approach directions A, B and C (delivery state)
Medium-resistant stainless-steel version Robust, tough and largely media resistant. Critical components such as plugs, cover screws and guide bushes, etc., consist of high-quality inox steel. Approach direction Horizontal Can be adjusted in 180° steps Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Guard locking type
CTP?L1Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle)
Escape release This is used for manual release of guard locking from the danger zone without tools. Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connecting cable
1 IMP Operating voltage of guard locking solenoid 24 V DC WH
2 UB Operating voltage of AP electronics 24 V DC BN
3 FO1A Safety output, channel 1 GN
4 FO1B Safety output, channel 2 YE
5 OI Diagnostic output GY
6 OD Door monitoring output PK
7 0 V UB Operating voltage of AP electronics 0 V BU
8 IMM Operating voltage of guard locking solenoid 0 V RD
Housing material
Metal material Stainless steel
Safety switch housing Fiber glass reinforced thermoplastic
Actuating button POM-C
Weight
Net 0,53 kg
Ambient temperature
At UB = 24V DC -20 ... +55 °C
Degree of protection IP67 / IP69 / IP69K
Resilience to vibration In acc. with EN IEC 60947-5-3
Mechanical life 1 x 106
Installation orientation Any
Ready delay max.1 s
Switching frequency max.0,5 Hz
Connection 1 plug connector M12, 8-pin
Approach speed 20 m/min
Guard locking principle Closed-circuit current principle
Locking force Fmax 3900 N
Locking force FZh 3000 N
Retention force 20 N
Extraction force 20 N
Actuating force 10 N
Overtravel 5 mm
Electrical connection ratings
Test-pulse interval min.100 ms
Test pulses max.0,3 ms
Operating voltage DC
UUB 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Current consumption
IUB 40 mA
IIMP 400 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Fusing
External (operating voltage UB) 0,25 ... 2 A
External (solenoid operating voltage IMP) 0,5 ... 8 A
Rated insulation voltage Ui max.50 V
Rated impulse withstand voltage Uimp max.0,5 kV
Power consumption 6 W
EMC protection requirements In acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1) 3
Safety class
EN IEC 61140 III
Switching load
According to UL 24V DC, class 2
Safety outputs FO1A / FO1B
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output FO1A / FO1B 1 ... 150 mA
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1,5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Off-state current Ir max.0,25 mA
Switch-on time max.400 ms
Discrepancy time
Both safety outputs max.10 ms In acc. with EN IEC 60947-5-3
Monitoring output OD
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Monitoring output OI
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Work area
Repeat accuracy R 10 %
Other
Additional feature Escape release actuated by pushing
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
Reliability values according to EN ISO 13849-1
Performance Level PL e
Category 4
PFHD 4.1 x 10 -9
Mission time 20 y
''